All manufactured devices are submitted to a combination of environmental factors, some of which are induced (vibration, noise, acoustics, etc.), and some of which are natural (dust, rain, sun, etc.). These factors affect how the product functions throughout its lifecycle and conditions the storage, transportation and use of the device.
At AT4 wireless we are aware of the importance of verifying these factors and therefore provide the industry with use of our facilities and highly qualified personnel in order to carry out the necessary environmental tests. We offer a wide range of test services aimed at companies working in the electric, electronic and mechanical industries.
Certifications
|
The AT4 wireless Environmental testing Laboratory is the only certified laboratory(*) in Spain for carrying out testing on capacitors based on CECC regulations (CENELEC Electronic Component Committee).
(*) Certification granted by the LCIE (Laboratoire Central des Industries Electriques)
|
|
Guaranteeing the reliability of your device
Environmental testing guarantees the reliability of a device throughout its lifecycle by verifying that the product genuinely adheres to all the basic requisites. The manufacturer is therefore able to guarantee the reliability and safety of the product for its entire lifecycle, or for the phase of the cycle that is considered the most important.
Advantages
- Automated facilities.
- The ability to adapt to international regulations and the requirements of each manufacturer.
- The size and variety of the facilities.
- The experience and professionalism of the technical personnel.
- A flexible schedule and short response times.
Reference to standards
Test types
- Cold
- Dry heat
- Steady state damp heat
- Vibration (senoidal)
- Saline mist
- Temperature change
- Solderability
- Shock
- Tremor
- Cyclical damp heat
- Broadband random vibration
- Combined temperature-humidity cycle
- Climatic sequence
|
Services
Temperature and humidity testing
Maximum volume of 2170 x 1300 x 1930 mm.
Temperature range from -70ºC to +180ºC.
Relative humidity range from 10% to 98%.
Thermal shock testing
Maximum volume of 470 x 650 x 400 mm.
Temperature range from -80ºC to +220ºC.
Saline mist test
Maximum capacity of up to 1000 litres.
Maximum volume of 1300 x 770 x 900 mm.
Vibration testing
Types of tests: sine, random, shock and tremor.
Dynamic force of 17,792 N sine and peak.
Acoustic noise
IP level testing
Protection from dust and rain.
Component testing
Electric measurements.
Solderability.
Passive flammability.
Endurance.
Load and discharge.
High energy impulses and dielectric rigidity.